| HOBO®
Carbon Monoxide Logger

|
|
Monitor carbon monoxide (CO) levels in areas
such as garages, terminals, loading docks, construction sites, furnace
rooms, office buildings and living areas. Convenient battery operation
eliminates the need to run wires for AC power, making it easy to deploy
the HOBO CO logger at various potential hotspots. Use the resulting data
to help identify problems with furnaces, vehicles, water heaters,
stoves, fireplaces, ventilation, air supplies, and flues (non-condensing
environments only). Optimize resolution and accuracy with three
software-selectable ranges: 0 to 125 ppm, 0 to 500 ppm, 0 to 2000 ppm
(parts per million).
Important: The HOBO
Carbon Monoxide logger is a data recording device only. The data logger
does not replace the need for safety/warning alarm that alerts personnel
when carbon monoxide exposure reaches dangerous levels.
|
Features
and specifications
- Capacity: 32,520 measurements total
- User-selectable sampling intervals: 0.5
seconds to 9 hours, recording times up to 1 year
- Readout and relaunch with optional HOBO
Shuttle or HandCar
software running on a Palm® handheld
- Wall or ceiling mounting kit (hook/loop
and screws included)
- Programmable start time/date
- Memory modes: stop when full,
wrap-around when full
- Nonvolatile EEPROM memory retains data
even if battery fails
- Blinking LED (blue) confirms operation
- User-replaceable battery lasts 1 year in
normal applications*
- Battery level indication at launch
- Expected sensor life: 5 years
- Operating range: -20°C to +50°C (-4°F
to +122°F), 10 to 95% relative humidity, non-condensing, non-fogging
- Operating pressure range: 1 Atmosphere
± 10%
- Time accuracy: ±1 minute per week at
+20°C (+68°F)
- Size/Weight: 5.7 x 2.6 x 1.6" (144
x 60 x 40 mm)/ approx. 0.29 lbs. (0.13 kilograms)
* Battery life is shorter when CO levels
average 10 ppm or more. For example, battery life is 6 months at average
concentrations of 100 ppm.
|
|
|
Measurement
Specifications
| Nominal
Range (ppm) |
Actual
Range (ppm) |
Resolution
(ppm) |
Accuracy |
| 0 - 125 |
0.2 - 124.3 |
0.5 |
±1 ppm ±10% |
| 0 - 500 |
1 - 497.1 |
2 |
±3 ppm ±10% |
| 0 - 2000 |
4 - 1988 |
8 |
±5 ppm ±10% |
The CO sensor is temperature compensated
over the entire operating range; however, very rapid temperature changes
can contribute as much as an additional 10% error to the above accuracy
specifications.
Physical shocks or rapid changes in ambient
pressure may show up as spikes in the data.
Response time: 11 minutes typical,
depending on installation location and orientation.
Exposure level
reference
| 0-1 ppm |
Normal background |
| 9 ppm |
ASHRAE Standard 62-1989 for living areas |
| 50 ppm |
OSHA enclosed space 8-hour average levels** |
| 100 ppm |
OSHA exposure limit** |
| 200 ppm |
Mild headache, nausea, fatigue, and dizziness |
| 800 ppm |
Convulsions and death within 2-3 hours |
** U.S. Department of Labor Occupational
Safety & Health Administration (OSHA) regulation 1917.24: The CO
content in any enclosed space shall be maintained at not more than 50 ppm
(0.005%). Remove all personnel from enclosed space if the CO concentration
exceeds 100 ppm (0.01%).
|
| Description |
Part No. |
Price
|
| HOBO Carbon Monoxide Logger |
H11-001 |
$220 |
| Replacement Vents with filters |
HRV-CO |
$5 |
| HOBO Shuttle (optional) |
H09-003-08 |
$159 |
| |
|
|
| Software Starter Kits |
|
|
| BoxCar Pro 4.3 Starter Kit
(Windows) |
BCP4.3-ON |
$95 |
| BoxCar 3.7 Starter Kit (Windows) |
BC3.7-ON |
$20
|
|
|