Features and specifications
• Intrinsically Safe Rating
(by US standards): IS, Class I, II, Division 1, Groups A-G,
Temperature Code T4 (<=135°C); NI, Class I, Division 2, Groups A-D,
Temperature Code T4 (<=135°C); S, Class II, Division 2, Groups F and
G; as specified in the US National Electric Code and approved by Factory
Mutual
• Environmental Rating: tested to
NEMA 6 (IP67); not intended for prolonged deployment
in water or extended exposure to epoxy-permeating vapors
• Uses optic communications through the Optic Base Station™ with the StowAway-IS
Coupler for launch and readout*
• Readout and relaunch with optional Optic Shuttle™ and StowAway-IS Coupler*
• Operating Temperature Range**: -40°F to +167°F (-40°C to +75°C)
• Operating Humidity Range:
at 0-100% RH and <+86°F (+30°C): continuous exposure
at 0-95% RH and >+86°F (+30°C): continuous exposure
at 95%-100% RH and >+86°F (+30°C): max of 10 weeks
Note: exposure to continuous moisture above +86°F (+30°C) for more
than 10 weeks may affect temperature accuracy
• Recommended Storage Temperature: -40°F to +122°F (-40°C to +50°C); storage
outside this range will reduce battery life
• User-selectable sampling intervals of 0.5 seconds to 9 hours
• Time Accuracy: ±1 minute per week at +68°F (+20°C)
• Capacity: 32,520 measurements total
• Programmable start time/date
• Triggered start on location with StowAway-IS Coupler or magnet
• Memory Modes: stop when full, wrap-around when full
• Non-volatile memory retains data even if battery fails
• Blinking LED light shows if temperature exceeds user-determined limits
• Multiple sampling with minimum, maximum, and averaging
• Size: 1.5" diameter x 0.8" thick (38 x 20mm), with 0.4"
(10mm) mounting bail; hole diameter 3/16" (5mm)
• Weight: 1.1oz (32g)
• Battery: 1/10 D, 3.6 Volt Lithium, non-replaceable; Battery Life: 5
years continuous use with a logging interval >=10 minutes and multiple
sampling disabled
• Compliance certificate available (call for details)
• NIST-traceable temperature accuracy certification available (call for
details)
Measurement
Resolution and Accuracy
• Temperature Accuracy: ±0.72°F (±0.46°C) at +68°F
(+20°C), see Plot A for temperature accuracy over the complete operating
temperature range
• Temperature Resolution: 0.63°F (0.35°C)
at +68°F (+20°C), see Plot A for temperature resolution over the complete
operating temperature range
• Precision components eliminate the need
for user calibration
• Response Time: <60 minutes in still
air
| Description |
Part
No. |
Qty 1-9 |
10-99 |
100+ |
| StowAway-IS Temp logger |
TBIB-40+75-IS |
$165
|
$153
|
$140
|
| Accessories |
|
|
|
|
| Optic Base Station |
DSA |
$80 |
$74 |
$68 |
| StowAway-IS Coupler |
TBIB-IS-Coupler |
$15 |
- |
- |
| BoxCar Pro 4.3 Starter Kit (Windows) |
BCP4.3-ON |
$95 |
$87 |
$80 |
| BoxCar 3.7 Starter Kit (Windows) |
BC3.7-ON |
$20 |
$18 |
$17 |
* The Optic Base Station and Optic Shuttle
are not rated Intrinsically Safe.
** Measurement range may differ from operating range due to precision