StowAway Voltage Logger

StowAway Volt logger

The StowAway Volt is a feature packed, general purpose logger that can be set up for numerous voltage logging applications. Start the logger, readout and plot the data with BoxCar® Pro (Windows) or LogBook® (Mac) software.

 

Features

Voltage range from 0 to 2.5 volts
Accuracy ±10 mV, ± 0.5% of reading
Two year battery life (user replaceable)
Nonvolatile EEPROM memory retains data even when battery is removed
Safe operating temperature range of -40°C to +75°C, non-condensing
Small size: 1.8" tall x 1.9" wide x 0.6" thick and 0.9 oz.
Sampling intervals from 0.5 seconds to 4.8 or 9.0 hours, depending on the software
Blinking LED light confirms operation
Data exportable to spreadsheet programs (Lotus, Excel, etc.)
Memory configurations are 2K, 8K or 32K storing 1800, 7944 or 32,520 measurements
Alarm indication
Delayed launch (up to three months)
Push button triggered start
Multiple sampling with minimum, maximum, or averaging

 

INPUT and GND (ground)
The logger measures the voltage difference between the INPUT and GND lines. It properly handles signals connected to the INPUT line if they are between 0 and 2.5 volts with respect to GND. The INPUT line should never be exposed to voltages less than -0.2 V or greater than 3.5 V with respect to GND.

BAT
BAT is available to provide power to external circuitry. This is the same battery that powers the logger; any power drawn from it will reduce its normal two year operational life. The 3.5 volt battery has a capacity of 370 mAh.

SENSETiming Diagram
The SENSE line can be used to enable power to the sensor with external circuitry only during the time a measurement is actually being made. See Timing Diagram.

Calibration
The logger's accuracy is guaranteed by using precision parts. It has no calibration adjustments. To ensure proper part function and assembly operation, each StowAway Volt is tested for accuracy at eight different voltages.

Timing
Input is active for 15 milliseconds during measurement. The actual A-D reading occurs 2 milliseconds after the sense line goes high. See Timing Diagram.

Input characteristics
The logger has a ±0.1µA maximum leakage while disconnected and a ± 0.4 µA maximum leakage while connected. The sense line and analog input line each have a 100K series resistor to help protect them from out-of-range inputs. The BAT line is not protected by a series resistor.

 


Ordering Information
Description Part No.

Qty 1-9

10-99

100+

2K StowAway Volt logger (0 to 2.5 volts DC) SVB02

$151

$136

$129

8K StowAway Volt logger (0 to 2.5 volts DC) SVB08

$171

$154

$146

32K StowAway Volt logger (0 to 2.5 volts DC) SVB32

$246

$221

$210

       
BoxCar Pro 4.3 Starter Kit (Windows) BCP4.3-ON
$95
$88
$81
BoxCar 3.7 Starter Kit (Windows) BC3.7-ON
$14
-
-
       
Replacement batteries (box of 10) HRB

$60

-

-

*This is a limited time price reduction.

Note: A starter kit is required to operate the StowAway Volt logger. Each starter kit includes software, computer interface cable and software manual.